BTU-1 Boil-Off Gas Liquefaction System
- Domyślny opis krótki
The BTU-1, ensures unlimited storage time, avoids venting into the atmosphere and guarantees a perfectly conditioned liquid for your station:
- High-capacity onsite liquification up to 48 Nm3/h.
- Minimal start-up time
- Integrated PLC with control logic for autonomous operation.
- Removes the need for active management of storage pressure and eliminates the need for Nitrogen consumption and logistics, significantly reducing the required man-hours, energy consumption, and total cost of ownership
- Allows for minimal civil works and onsite constructive time, and even has possibility to be relocated.
- Plug & Play modular design. Can work with any LNG storage tank with a liquid and vapour connection
Design Specifications (BTU-1)
input output
Design pressure: 3.0 – 10.0 barg 3.0 – 10.0 barg
Design temperature: -150c to -120c -145c to -122c
Vapour fraction: 100% 0%
Medum Composition: Boil-Off Gas from LNG LNG
Methane (CH4) > 90mol% > 98.3mol%
Ethane (C2H6) < 0.5mol% < 0.1mol%
Hydrocarbons >C2 < 0.1mol% < 0.1mol%
Carbon Dioxide (CO2) < 50ppm < 50ppm
Nitrogen (N2) < 10mol% < 1.7mol%
Design Specifications (BTU-1)
Outside temperature: -25C to +35C
Humidity (RH): Max 85%
Earth-quake zone: Eurocode 8
Max wind load: 160 km/h
Design Codes
PED 2014/68/EU Pressure Equipment Directive
ATEX 114 and 153 EX-standards EC94/9/EC
Type Certificate Model B
ASME VIIII & AD2000
EN1473
General Specifications (BTU-1)
Required power supply: 400V 3-phase+N+E/50Hz max 100 amp
Installed power: 37 kW
Compression: Gas compressor
Cooling: Cascade cooling configuration
Refrigerants: Natural refrigerants for GWP reduction directive
System Connections
BOG feed connection Three-piece 3⁄4” coupling
welded to BTU/VIP piping
LNG return connection Three-piece 3⁄4” coupling
welded to BTU/VIP piping
Process Design
Start-up time: 10 – 30 minutes
Feed capacity: 35 kg/h BOG input (max 48 Nm3/h)
Production capacity: 17.7 to 22.0 kg/h
Energy usage: .56 kWh/kg feed gas
BTU-1 Remote Performance Management
We offer an extensive suite of remote services, including remote
performance management of your BTU-1 unit to ensure superior
availability to maximize re-liquefaction.