VIA set MAIN CONTROL PANEL SCC8 + POWER DISTRIBUTION UNIT SPDU-52
ID produktu: 49212
Opis produktu
VIA set MAIN CONTROL PANEL SCC8 + POWER DISTRIBUTION UNIT SPDU-52
VIA is a combination of a control panel and a versatile power distribution unit. Designed to monitor and control power, liquid levels, temperatures, heating, and more on your motorhome, campervan or RV.
Scope of delivery
1x VIA Control Panel
1x Power Distribution Unit SPDU52
Technical charcteristics of individual elements
SCC8 CARAVAN CONTROL 8 BUTTON CLASSIC V1 BLACK
Operating Voltage range: 6 - 22 VDC
Operating Temperature range: From -20°C up to 70°C
Power consumption at 12 V Operating, WiFi On, 100 % illumination: 100 mA
Power consumption at 12 V Operating, WiFi Off, 70% illumination: 40 mA
Power consumption at 12 V Operating, WiFi Off, 0% illumination: 22 mA
Power consumption at 12 V Power Off, logger still active: 5 mA
Display capabilities - Current Range: -999.99 to +999.99 A
Display capabilities - Current Resolution: 0.01 A
Display capabilities - Voltage Range: 0 - 75 VDC
Display capabilities - Voltage Resolution: 0,001 V
Display capabilities - Voltage Amp hours (Ah): ±0,1 Ah
Display capabilities - Temperature Range: -40°C up to + 150°C
Display capabilities - Temperature Resolution: 0,1°C
WIFI Radio Frequency Band: 2,4 GHz
Connectivity UP TO number of Batteries: 6
Connectivity UP TO number of Shunts: 24
Connectivity UP TO number of Temperature sensors: 10
Connectivity UP TO number of Tank level sensors: 14
Connectivity UP TO number of Inclinometer sensors: 2
Length, mm: 157.1
Width, mm: 82.1
Height, mm: 5.6
SPDU-52 POWER DISTRIBUTION UNIT
Operating Voltage range: 8 - 22 VDC
Operating Main battery: 8 - 22 VDC
Operating Starter battery: 8 - 22 VDC
Operating Temperature range: From -20°C up to 70°C
Power consumption at 12 V Operating: 15 mA
Power consumption at 12 V Power off: 0,25 mA
Current measuring Channel 1 (solar): 0 - 16 A
Current measuring Channel 2 (charger): 0 - 40 A
Current measuring Channel 3 (main battery): 0 - 50 A
Current measuring Channel 4 (starter battery): 0 - 50 A
Current measuring Accuracy: ±1 %
Current measuring Sampling rate: 100 ms
Current measuring Resolution: ±0.01 A
Voltage measuring Channel 1 (starter battery bank): 0-22 V
Voltage measuring Channel 2 (main battery bank): 0-22 V
Voltage measuring Channel 3 (U3): 0-75 V
Voltage measuring Channel 4 (U4): 0-75 V
Voltage measuring (U1, U2, U3, U4) Accuracy: ±0,3 %
Voltage measuring (U1, U2, U3, U4) Resolution: 1 mV
Voltage measuring (U1, U2, U3, U4) Sampling rate: 100 ms